1. Registering transparent labels for dispensing
A label dispenser can guide its web through the 3 mm fork and use each label-to-liner transition as a registration input. Ultrasonic sensing avoids dependence on optical contrast, while two-point or dynamic teach-in sets the threshold for the material. The stated 2 mm minimum label size and gap depend on label thickness.
Problem Solved
A transition signal identifies the label boundary for the machine controller, helping coordinate web stopping and dispensing when the label and backing provide little optical contrast.
Ultrasonic
Teach-in
3 mm fork
2. Counting labels during roll preparation
A roll preparation station can pass the label web through the fork and count discrete changes between labels and their gaps. PNP and NPN outputs provide the switching events for compatible machine inputs. The typical 1.5 kHz frequency is conditional on material and speed, so the web rate must respect the qualified setup.
Problem Solved
Counting the qualified label transitions gives the winding controller a quantity input for preparing rolls, allowing the machine sequence to compare the accumulated count with its target.
PNP/NPN
Label detection
1.5 kHz typical
3. Checking single and double material layers
A sheet handling station can qualify an ultrasonic threshold to distinguish a single layer from overlapping material within the fork. The UF family documents single- and two-ply material differentiation; sensitivity buttons and teach-in provide the adjustment means. The actual materials and thicknesses must be checked with the installed transport before using the switching result.
Problem Solved
A qualified layer-dependent signal helps the handling controller identify an unexpected overlap before the next processing step, reducing the chance of feeding two sheets as one item.
Layer detection
Sensitivity adjustment
Teach-in