SICK 6049678 UFN3-70B413 Ultrasonic Fork Sensor

SICK 6049678 UFN3-70B413 Ultrasonic Fork Sensor

USD 462.02

UFN3-70B413 combines ultrasonic label detection, a 3 mm fork, two-point and dynamic teach-in, PNP/NPN outputs, an M8 connector and IP65 housing.

SKU: SICK-6049678 Category:
SICK UF

SICK UFN3-70B413 Ultrasonic Fork Sensor

BrandSICK
Model IdentifierUFN3-70B413
Official Part Number6049678

Technical Overview

The SICK UFN3-70B413 is an ultrasonic fork sensor for detecting labels within a 3 mm opening and 69 mm fork depth. Its acoustic principle supports label detection without relying on optical contrast. The minimum specified label size and gap are 2 mm, depending on label thickness. Plus/minus buttons adjust sensitivity and light/dark switching, with two-point and dynamic teach-in available for setup. PNP and NPN outputs connect to machine inputs, while response of no more than 250 µs and typical 1.5 kHz switching support repeated transitions subject to material and speed. An M8 four-pin connector and IP65 aluminum housing support installation.

Ultrasonic fork sensor with 3 mm opening, PNP/NPN outputs, adjustable light/dark switching, M8 four-pin connector and IP65 aluminum housing.

Key Features

  • Ultrasonic label detection
  • 3 mm fork opening; 69 mm fork depth
  • Minimum label size and gap 2 mm, depending on label thickness
  • Plus/minus buttons for sensitivity and light/dark switching
  • Two-point and dynamic teach-in
  • PNP and NPN switching outputs
  • Response ≤250 µs; typical 1.5 kHz switching, material/speed dependent
  • 10–30 V DC supply; 100 ms initialization
  • M8 four-pin male connector
  • IP65 aluminum housing; +5 to +55 °C operation

Set an ultrasonic threshold for label detection with two-point or dynamic teach-in and local sensitivity adjustment.

Technical Specification Matrix

ParameterValue
Functional principleUltrasonic detection principle
Housing formFork shaped
Fork width3 mm
Fork depth69 mm
Label detectionSupported
Minimum detectable objectLabel size / gap between labels: 2 mm, depending on label thickness
AdjustmentPlus/minus buttons: teach-in, sensitivity and light/dark switching
Teach-in mode2-point and dynamic teach-in
Power supply10–30 V DC; reverse-polarity protected; short-circuit-protected network max. 8 A
Residual ripple<10%; remain within supply-voltage tolerance
Current consumption40 mA without load
Initialization time100 ms
Switching outputPNP and NPN
Switching modeLight/dark switching, selectable via buttons
Switching frequency1.5 kHz typical at light/dark ratio 1:1, depending on material and speed
Response time≤250 µs
Output current100 mA; minimum 0.3 mA
ConnectionMale connector M8, 4-pin
Circuit protectionSupply reverse-polarity protection; Q short-circuit protection; interference pulse suppression
Protection classIII; reference voltage 50 V DC
Housing materialAluminum
IP ratingIP65
Operating temperature+5 to +55 °C
Storage temperature−20 to +70 °C
Shock resistanceEN 60068-2-27
MTTFD207 years
Diagnostic coverage DCavg0%
UL fileNRKH.E191603 and NRKH7.E191603
Dimensions L x W x H (cm)9.25 x 1.8 x 4.75
Physical Weight (kg)0.095

Industrial Applications

1. Registering transparent labels for dispensing

A label dispenser can guide its web through the 3 mm fork and use each label-to-liner transition as a registration input. Ultrasonic sensing avoids dependence on optical contrast, while two-point or dynamic teach-in sets the threshold for the material. The stated 2 mm minimum label size and gap depend on label thickness.

Problem Solved

A transition signal identifies the label boundary for the machine controller, helping coordinate web stopping and dispensing when the label and backing provide little optical contrast.

Ultrasonic Teach-in 3 mm fork

2. Counting labels during roll preparation

A roll preparation station can pass the label web through the fork and count discrete changes between labels and their gaps. PNP and NPN outputs provide the switching events for compatible machine inputs. The typical 1.5 kHz frequency is conditional on material and speed, so the web rate must respect the qualified setup.

Problem Solved

Counting the qualified label transitions gives the winding controller a quantity input for preparing rolls, allowing the machine sequence to compare the accumulated count with its target.

PNP/NPN Label detection 1.5 kHz typical

3. Checking single and double material layers

A sheet handling station can qualify an ultrasonic threshold to distinguish a single layer from overlapping material within the fork. The UF family documents single- and two-ply material differentiation; sensitivity buttons and teach-in provide the adjustment means. The actual materials and thicknesses must be checked with the installed transport before using the switching result.

Problem Solved

A qualified layer-dependent signal helps the handling controller identify an unexpected overlap before the next processing step, reducing the chance of feeding two sheets as one item.

Layer detection Sensitivity adjustment Teach-in